AMADA, PULSAR LC2415XLIII, 3000 WATT, W/LMP3015A 6-SHELF AUTOMATION. MFG: 2002

Motion Package
Travel Method
X axis for work piece movement, Y axis for cutting head movement

Control Method
X, Y & Z simultaneous 3 axis control and B axis

Drive Motors
FANUC AC Servo (X, Y, Z and B)

Maximum Sheet Size
61" (Y) x 198" (X) with one repositioning cycle

Maximum Axis Travel
61" (Y) x 99" (X) x 11.8" (Z) x 0.78" (B)

Maximum Cutting Speed
2362 IPM

Maximum Table Speed
3,149 IPM. per axis (4,454"/min. 45O vector)

Maximum Speed - Z-Axis
2362 IPM

Positioning Accuracy 1
0.0004"/20"

Repeatability
0.0002"

Maximum Material Weight
727 lbs. (5' x 10' x 3/8" or 4' x 8' x 1/2")

Number of Clamps
3

Work Chute
66" (Y) x 21" (X)

Assist Gas
4 ports, part program selectable

Machine Size (WxDxH)
99" x 225" x 90"

Machine Weight
13,640 lbs including laser resonator

Electrical Requirements
208 VAC, 3 phase, 60 Hz., 10 KVA


(1) Processing accuracy will be different

CNC Controller
Model
FANUC 160i-L - 32 bit

Display
LCD Color Graphics Display

Control Function
X, Y,Z, and B Simultaneous 3 Axis and B axis
Laser Power Control (CW, Gated Pulse)

Input Method
MDI, Edit, DNC or 3" PC Compatible Floppy Disk

Minimum Command Unit
0.0001" (X, Y, Z)

Minimum Travel Unit
0.0001" (X, Y, Z)

Standard Memory
128K (320m)

Optional Memory
Expandable to 256K or 512K

Operating Modes
Automatic, MDI & Manual

Display Modes
Program Contents, Position Information, Program Check, Settings, Parameters,

Beam Diameter Compensation, Assist Gas Status, Self Diagnostics

Interlock Displays
Water Temperature, Gas Pressure, Vacuum Leak, Blower Malfunction, Shutter

Power, Discharge, Assist Gas, Door Open

Electrical Requirements
Included in Machine Requirements