A & A Machinery Sales Inc
201 Dean Sievers Pl
Morrisville
PA
19067-3700
Tel: 215-428-1100
Fax: 215-428-9008
aasales@aamachinery.com
www.aamachinery.com
EISENMANN, No. VRT0-C, Thermal Oxidizer Series 5000 VRT0-C, 2001
[103]

RTO System
Eisenmann Thermal Oxidizer Series 5000
Machine Data
VRTO-C Data
Max Exhaust Stream: 43,305 SCFM
Exhaust Inlet temp: 160 Deg F
Combustion Temp: 1500 Deg F
Combustion Temp High Limit: 1800 Deg F
VRTO-C Outlet Temp: 250 Deg F
∆T: 90 deg F
∆P: 23.7 W.C.
Rotor Size: Type -2100 Ø, 8-spoke
Cycle time: 1 min
Design Solvent Load: 200 lb/hr
GAS TRAIN & BURNER
Fuel: Natural Gas, 1,000 Btu/hr
Burner Cap: 5mm Btu/hr
Burner Type: Kinemax 4 From Maxon
Exhaust Fan:
Type: 490 HIB belt Drive, 350 HP, 1800 rpm, 460 v
Combustion Blower: 15 hp, 3600 rpm, 460 v
Additional information from Manual can be faxed upon request
Combustion Air Blower Specs
Maxon Corp.
Model: C-6060-24
Description: Pressure Blower w/ TEFC Motor
SCFM: 1010
Pressure: 41 W..C.
Discharge Size: 6
HP: 10
Syn RPM: 3600
Electric: 460 V
Exhaust Fan Specifications
Manufacturer: Twin City
Model: 490 HIB, Belt Drive
Design Temp: 160 Deg F at 27.6 W.C.
Volumetric Flow Rate: 43,305 SCFM-58,974 ACFM
HP: 350
RPM: 1800
Electric: 460 V
Max Temp: 500 Deg F
System has been disconnected and brought back to our warehouse
UED-ed is published by
Used Equipment Directory
45 Eisenhower Dr 5th Fl, Paramus NJ 07652
Robert Scofield, Publisher. Email: bobs@buyused.com,