October 2008
Belyea Co Inc
2200 Northwood Ave
Easton PA 18045-2239
Tel: 610-515-8775 Fax: 610-258-1230
info@belyeapower.com www.belyeapower.com

22500 KW, Inlet 600 PSIG/750 DEGF, AE 140 PSIG, EXH:1.5" HGA, 13.8 KV, 1993 :-1 [33810]




STOCK# 12097A

STEAM TURBINE:

SERIAL NUMBER: 155340
MANUFACTURER: GENERAL ELECTRIC

RATING: 22500 KW

INLET STEAM: 600 PSIG/750 DEG F

EXTRACTION STEAM: 140 PSIG

0-180,000 LBS/HR

ADMISSION STEAM: 95 PSIG

0-50,000 LBS/HR

EXHAUST STEAM: 1.5" HGA, AXIAL EXHAUST

MAXIMUM INLET STEAM FLOW: 210,000 LBS/HR

RATING WITH ZERO EXTRACTION:

AND ZERO ADMISSION 20 MW

STEAM RATE ZERO EXTRACTION:8.8 LBS/KW

SPEED: 3600 RPM

NUMBER OF STAGES: 12

GOVERNOR: WOODWARD 505E



GENERATOR:
SERIAL NUMBER: 316X901
MANUFACTURER: GENERAL ELECTRIC
RATING: 25,000 KVA
VOLTS: 13800 V, 3 PHASE, 60 HZ

AMPS: 1046
FIELD AMPS: 376 EXCITATION

VOLTS: 250 V
POWER FACTOR: 0.9
CONDENSER: SURFACE AREA: 19,574 SQ. FT
STEAM LOAD: 204,896 LBS/HR
CIRCULATING WATER FLOW: 23,365 GALS/MIN

SCOPE OF SUPPLY: STEAM TURBINE GENERATOR SKID MOUNTED COMPLETE

CONDENSER WITH WATER ISOLATION VALVES AIR EJECTOR PACKAGE LUBE

OIL SYSTEM WITH LUBE OIL COOLER CONTROL OIL SYSTEM TURBINE

CONTROL PANEL GENERATOR BREAKER AND CONTROL PANEL GLAND STEAM

SYSTEM COOLING WATER PUMPS WITH MOTOR (3 PCS) CONDENSATE PUMPS

WITH MOTOR (3 PCS)
HISTORY: YEAR BUILT: 1993
YEAR SHUTDOWN: 2008

YEAR LAST OVERHAUL: 2000

UNIT IS VERY GOOD CONDITION AND IT WAS STANDY UNTIL JUNE 2008.


UED-ed is published by
Used Equipment Directory 45 Eisenhower Dr 5th Fl, Paramus NJ 07652
Robert Scofield, Publisher. Email: bobs@buyused.com, Tel: 973-400-1790 Fax: 973-625-8933