158955 KW, Inlet 1300 PSIG/950 *F, Exh. 2" HGA, 18 KV, 1990:-2
[33365]

STEAM TURBINE:
MANUFACTURER: GE
RATING: 158,955 KW
INLET STEAM: 1300 PSIG/950 DEG F
MAXIMUM INLET STEAM FLOW: 1,332,536 LBS/HR
TYPE: TANDEM COMPOUND ,NON REHEAT
EXHAUST: 2" HGA
GUARANTEED HEAT RATE: 8572 BTU/KWH, Net Plant heat rate
approx 12,000 btu/kw. Steam generated from coal fired boilers.
LAST STAGE BUCKET: 26"
SPEED: 3600 RPM
GENERATOR:
MANUFACTURER: GE
TYPE: ATB-2
RATING: 193,000 KVA
VOLTAGE: 18 KV, 3 PHASE, 60 HZ
COOLING: HYDROGEN
EXCITATION VOLTAGE: 375 V
HISTORY:
YEAR COMMISSIONED: 1991 new turbines replaced the
original units from the mid 1950's.
YEAR SHUTDOWN: 2007
SCOPE OF SUPPLY:
COMPLETE UNIT WITH OUTDOOR ENCLOSURE.