Belyea Co Inc
2200 Northwood Ave
Easton
PA
18045-2239
Tel: 610-515-8775
Fax: 610-258-1230
info@belyeapower.com
www.belyeapower.com
17000 KW, Inlet 850 PSIG/900*F, 13800 V., GE, 1884, WOOD FIRED POWER PLANT:-1
[33221]
STEAM TURBINE:
MANUFACTURER: GE
RATING: 16972 KW
PRESSURE TEMPERATURE FLOW
INLET STEAM: 850 PSIG 900 DEG F 135,000 LBS/HR
EXHAUST STEAM: 1.5 HGA
STEAM RATE: 7.94 LBS/KWH
MINIMUM STEAM FLOW: 11,900 LBS/HR
SPEED: 3600 RPM
GOVERNOR: WOODWARD 505
ROTATION (STEAM FLOW): CCW
GENERATOR:
MANUFACTURER: GE
RATING: 20,000 KVA
VOLTAGE: 13800 V, 3 PHASE, 60 HZ
PF: 0.95
SPEED: 3600 RPM
ARMATURE AMPS: 837 AMPS
EXCITER: BRUSHLESS, PMG
TYPE: TEWAC
CONDENSER: ECOLAIRE, 16,030 SQ. FT, SIZE 32F-RG-22
SCOPE OF SUPPLY:
STEAM TURBINE MULTIVALVE, MULTI STAGE WITH INLET VALVE RACK
GENERATOR WITH EXCITER
INLET STEAM PIPE AND STOP VALVE
CONDENSATE EXTRACTION PUMPS WITH MOTOR
TURBINE CONTROL PANEL
GENERATOR CONTROL AND PROTECTION PANEL
SPARE PARTS
MANUALS, DRAWINGS AND HISTORY RECORDS.
BOILER:
KEELER DORR OLIVER
BOTTOM SUPPORT
140,000 PPH
1050 PSIG
920 DEG. F
DEMIN. SYSTEM:
ECOWATER SERIES DH TWO COLUMN DEIONIZER
PLANT CONSISTS OF A SINGLE SYSTEM WITH A FUEL BIN AND BOILER.
TURBINE/GENERATOR, WATER COOLED CONDENSER AND ASSOCIATED ANCILLARY EQUIPMENT.
BOILERS OPERATE WITH AN UNDERFIRE STOKER SYSTEM. THE BUILDING AND A WIDE
RANGE OF SPARE PARTS ARE INCLUDED.
PLANT BUILT IN 1985 AND RUN UNTIL 1993. RESTARTED IN OCTOBER 2000 AND RAN
UNTIL APRIL 2001. SHUTDOWN DUE TO LOSS OF FUEL SOURCE. FUEL IS PRIMARILY
MILL RESIDUES, BARK AND CHIPS.
UED-ed is published by
Used Equipment Directory
45 Eisenhower Dr 5th Fl, Paramus NJ 07652
Robert Scofield, Publisher. Email: bobs@buyused.com,
Tel: 973-400-1790 Fax: 973-625-8933
|