5200 KW, SOLAR TAURUS 60, 13200 V, 2001, 1800 RPM, MOBILE, RENTAL OR PURCHASE-2 [32359]



TURBINE GENERATOR SET MODULE:

TAURUS 60 MOBILE GENERATOR SYSTEM
TAURUS 60 GAS TURBINE WITH SoLoNOx, DRY LOW NOx COMBUSTION SYSTEM
EPICYCLIC REDUCTION GEARBOX, 1800 RPM OUTPUT SPEED
SALIENT POLE, 3 PHASE GENERATOR
13800 VOLTS
3 PHASE
60 HERTZ
RATED PER NEMA STANDARDS SO THAT THE GENERATOR WILL NOT LIMIT TURBINE

PERFORMANCE OVER THE RANGE OF SITE AMBIENT TEMPERATURES.
SLEEVE BEARINGS WITH PRESSURE FED SUMPS
SIX-LEAD WYE CONNECTION
TERMINAL BOX
FORM WOUND STATOR WINDINGS
DAMPER WINDINGS
ROTOR BALANCE TO 125% RATED SPEED
PERMANENT MAGNET PILOT EXCITER
ANTI-CONDENSATION SPACE HEATERS
300% SHORT CIRCUIT CAPABILITY FOR 10 SECONDS
OVERLOAD CAPACITY PER NAME
150% RATED CURRENT FOR 1 MINUTE
110$ FOR 2 HOURS
VOLTAGE REGULATOR
SOLID STATE
SINGLE-PHASE SENSING
+/- VOLTAGE ADJUSTMENT RANGE
0.5% STEADY STATE VOLTAGE REGULATION
REACTIVE LOAD SHARING TO WITHIN 5% NAMEPLATE RATING
CROSSCURRENT COMPENSATION CAPABILITY
WAVE FORM CHARACTERISTICS
DEVIATION FACTOR (MAX) 6%
HARMONIC CONTENT (MAX) 3%
TELEPHONE INTERFERENCE FACTOR 50
BALANCED RESIDUAL 75
VOLTAGE DRIFT
THE CHANGE IN VOLTAGE WILL NOT EXCEED 1.0% OVER A 30 MINUTE PERIOD WHEN THE

GENERATOR IS OPERATING AT RATED VOLTAGE AND 0.8 TO 1.0 POWER FACTOR AND
WITH A CONSTANT LOAD BETWEEN NO LOAD AND FULL RATED LOAD.
OPEN DRIP PROOF GENERATOR PER NEMA STANDARDS
INSULATION CONFIRMS TO NAME CLASS F WITH CLASS (105 DEG. C) TEMPERATURE RISE
NATURAL GAS FUEL SYSTEM (DUAL FUEL OPTION)
REQUIRES FUEL MEETING THE REQUIREMENTS OF SOLAR SPECIFICATION ES9-98
NEC (NON-HAZARDOUS ELECTRICAL CLASSIFICATION)
DIRECT AC DRIVE START SYSTEM
LUBE OIL SYSTEM
TANK
FILTERS
PRE/POST LUBE PUMP
BACK-UP PUMP
VENT SEPARATOR
VIBRATION AND TEMPERATURE MONITORING SYSTEM
PLC BASED CONTROL SYSTEM WITH 120 VDC BATTERY SUPPLY (INSTALLED ON THE POWER

CONTROL MODULE)
GENERATOR CONTROL AND MONITORING SYSTEM
INTEGRATED MONITORING AND CONTROL OF THE GENERATOR IS PROVIDED USING A

SPECIALLY DESIGNED MODULE IN THE PLC TO RECEIVE INPUT DATA FROM POTENTIAL
AND CURRENT TRANSFORMERS. THE SYSTEM CAL-CULATES REAL AND REACTIVE POWER,

POWER FACTOR AND THE VARIABLES REQUIRED FOR SYNCHRONIZATION
AUTOMATIC SYNCHRONIZING
MOTORIZED VOLTAGE ADJUST
KW CONTROLLER
KVAR/POWER FACTOR CONTROLLER
TURBINE COMPRESSOR CLEANING
PIPING MANIFOLD FOR ON-CRANK CLEANING
WEATHERPROOF ACOUSTIC ENCLOSURE
VENTILATION SILENCERS AND FANS
LIGHTS
FIRE DETECTION AND GAS MONITORING SYSTEM WITH AUTO SHUTDOWN
AND FUEL SUPPLY SHUTOFF
HIGH TEMPERATURE DETECTION AND ALARM
DOCUMENTATION
INTERFACE DRAWINGS
OPERATION AND MAINTENANCE MANUALS
TEST REPORTS
INLET SYSTEM
BARRIER FILTER AND SILENCER MOUNTED ON TOP OF GENERATOR SET ENCLOSURE
EXHAUST SILENCER AND OUTLET EXTENSION PIPE (APPROXIMATELY 24' ABOVE GROUND)
FACTORY TESTING
GAS TURBINE ENGINE TESTING
GENERATOR TESTING
RADIOGRAPHY INSPECTION
QUALITY ASSURANCE
EMISSIONS TESTING
SHIPPING PREPARATION
TRI-AXLE TRANSPORT TRAILER WITH TWO AXLE PIVOTING BOOSTER
APPROXIMATE DIMENSIONS:
48'L PLUS 14'1" BOOSTER (REMOVABLE AT SITE)
8'6" W
9' ACROSS TRAILER AXLES
133" SWING CLEARANCE
49" 5TH WHEEL HEIGHT (LOADED)
AIR RIDE SUSPENSION AND AIR RAISE AND LOWER KIT
STEEL DISC WHEELS WITH 275/70R X 22.5 TIRES
THREE TAIL LIGHT PACKAGE
LANDING GEAR
6 ADDITIONAL LANDING LEGS WITH SOIL BEARING PLATES FOR LEVELING AND

STABILIZATION AT SITE
OVERALL TRANSPORT HEIGHT 14'2"


POWER CONTROL MODULE:

POWER CONTROL ROOM
PCR HVAC SYSTEM
GENERATOR MAIN CIRCUIT BREAKER
SINGLE INTERFACE POINT TO POWER GRID
AUXILIARY TRANSFORMER FEEDER CIRCUIT BREAKER
BUS PTS, FEEDER CTS, METERING CTS AND PTS, AND BECKWITH M-3425
PROTECTIVE RELAY
MODULE WITH THE FOLLOWING RELAYS:
IMPEDANCE (21)
REVERSE POWER PROTECTION (32)
LOSS OF FIELD PROTECTION (40)
NEGATIVE PHASE SEQUENCE PROTECTION (46)
PT BLOWN FUSE PROTECTION (60)
TIME OVERCURRENT PROTECTION (50/51 V)
NEUTRAL OVERCURRENT PROTECTION (51 N) - UTILIZED IN GROUNDED
SITE DESIGN
BUS GROUND FAULT DETECTION (59N) - UTILIZED IN UNGROUNDED SITE
DESIGN
GENERATOR DIFFERENTIAL FAULT PROTECTION (87 G)
ONE HIGH SPEED TRIPPING RELAY (86) FOR CIRCUIT BREAKER TRIP,
LOCKOUT AND TURBINE SHUTDOWNS
SETTINGS, PROGRAMMING AND TESTING
LIGHTNING ARRESTOR AND SURGE CAPACITOR
MONITOR CONTROL CENTER
SERVES TURBINE GENERATOR 480 VAC AUXILIARY LOADS
120 VDC TURBINE GENERATOR BATTERY SYSTEM AND CHARGER
DEDICATED 120 VDC SWITCHGEAR BATTERY SYSTEM WITH CHARGER
START MOTOR VARIABLE FREQUENCY DRIVE (VFD)
DC BACKUP LUBE OIL PUMP CONTACTOR
INTERIOR LIGHTING
PHOTOCELL CONTROLLED EXTERIOR LIGHTING AT ACCESS DOORS
EMERGENCY EYEWASH STATION
ANCILLARY EQUIPMENT
GAS TURBINE LUBE OIL COOLER
NEUTRAL GROUND RESISTOR
AUXILIARY LOAD TRANSFORMER (13.8 KV:480 V, 60 HZ)
ELIMINATES SITE REQUIREMENT TO SUPPLY 480 VAC SHORE POWER)
LIQUID FUEL BOOST PUMP AND AIR COMPRESSOR (WITH DUAL FUEL

OPTION)
TWO AXLE TRANSPORT TRAILER
46' L OVERALL
8'6" W
49" 5TH WHEEL HEIGHT (LOADED)
AIR RIDE SUSPENSION AND AIR RAISE AND LOWER KIT
STEEL DISC WHEELS WITH 255/70R X 22.5 TIRES
THREE TAIL LIGHT PACKAGE
LANDING GEAR
4 ADDITIONAL LANDING LEGS WITH SOIL BEARING PLATES FOR

LEVELING AND STABILIZATION AT SITE
OVERALL TRANSPORT HEIGHT 14'


APPROXIMATE WEIGHT:

TURBINE TRAILER - 120,000 LBS.
PCR TRAILER - 40,000 LBS.
MISC. TURBINE COMPONENTS TRAILER - 25,000 LBS.

PERFORMANCE:

EXPECTED POWER IS 5200 KW AND HEAT RATE IS 11,263 BTU/KWHR AT ISO

CONDITIONS (15 DEG. C/58 DEG. F). SITE SPECIFIC PERFORMANCE IS

AVAILABLE UPON SPECIFICATION IF SITE ELEVATION AND TEMPERATURE

CONDITIONS

EXHAUST TEMPERATURE 900 DEG. F

MANUFACTURED IN 2000
186 STARTS AND 1510 HOURS
226 STARTS AND 1522 HOURS