October 2008
Belyea Co Inc
2200 Northwood Ave
Easton PA 18045-2239
Tel: 610-515-8775 Fax: 610-258-1230
info@belyeapower.com www.belyeapower.com

75300 KW, Inlet 2400 PSIG/1050 * 15000 V/3/50 HZ, MITSUBISHI, 1995 - 1 [32106]






STEAM TURBINE:
MANUFACTURER: MITSUBISHI
RATING: 75,300 KW
INLET STEAM: 16.57 MPa (2400 PSIA)/566 DEG C
REHEAT PRESSURE: 97.99 KPa (150 PSIA)/538 DEG C
EXHAUST PRESSURE: CONDENSING
SPEED: 3600 RPM
NUMBER OF STAGES: 14
NUMBER OF EXTRACTION POINTS:3

GENERATOR:
MANUFACTURER: MITSUBISHI
RATING: 84,000 KVA
VOLTAGE: 15 kv, 3 phase, 50 hz
POWER FACTOR: 0.9
SPEED: 3000 RPM
TYPE: AIR COOLED

CONDENSER:
TYPE: DOUBLE FLOW
SURFACE AREA: 5,100 SQ. M
COOLING WATER: SEA WATER
COOLING WATER FLOW: 12,560 M SQ/HR
COOLING WATER INLET TEMP: 15 DEG C

YEAR BUILT: 1995
YEAR SHUTDOWN: 2004

SCOPE OF SUPPLY:
STEAM TURBINE GENERATOR WITH EXCITER
LUBE OIL TANK, LUBE OIL PUMP, LUBE OIL COOLER, CONDENSER, COOLING

WATER PUMPS, CONDENSATE EXTRACTION PUMP.


UED-ed is published by
Used Equipment Directory 45 Eisenhower Dr 5th Fl, Paramus NJ 07652