10000 KW, Inlet 64 bar/515 deg c, Ext. 21/13/1.2 Exh. Cond, 6300 v/3/50 hz:-1
[31581]
.
TURBINE:
MANUFACTURER ..................... SIEMENS
TYPE ............................. EENKS 32/36/96-3
NOMINAL RATING ................... 10,000 KW
DESIGN RATING .................... 6800 KW
INLET PRESSURE ................... 65 BARG, 64 T/H (NORMAL)
INLET TEMPERATURE ................ 515 DEG. C (NORMAL)
INLET PRESSURE MAX. .............. 80 BARG, 69 T/H
INLET TEMPERATURE MAX. ........... 520 DEG. C
EXTRACTION 1 ..................... 20.5 - 24 BARG, 15.2 - 25 T/H
EXTRACTION 2 ..................... 12.5 - 14 BARG, 23.4 - 35 T/H
BLEEDING ......................... 0.8 - 1.7 BARG, 1.8 - 6 T/H
EXHAUST .......................... 0.1 BARA, 22 - 26 T/H @ 46 DEG. C
SPEED ............................ 9000 RPM/1500 RPM
CONDENSER:
STEAM FLOW ....................... 26 T/H
SURFACE .......................... 185 M2
COOLING WATER TEMPERATURE INLET .. 15 DEG. C
COOLING WATER FLOW ............... 843 M3/H
GENERATOR:
MANUFACTURER ..................... SIEMENS
POWER ............................ 10000 KW, 12500 KVA
VOLTAGE .......................... 6300 V/3/50 HZ
COOLING SYSTEM ................... AIR/WATER
EXCITER .......................... THIRIPART
HISTORY:
YEAR ............................. 1979
TOTAL HOURS ...................... 120,000
LAST REVISION .................... 1998
DISMANTLED AND REFURBISHED ....... 2004
SCOPE OF SUPPLY:
COMPLETE TURBINE WITH ALL AUXILIARIES AND CONTROL SYSTEMS FOR SAFE OPERATION.
ALTERNATOR WITH PROTECTION, AVR, MAIN-SWITCH, NO SYNCHRONIZING SYSTEM.
DOCUMENTATION:
FULL DOCUMENTATION AND REPORTS AVAILABLE